Direct measurement of intracranial pressure at high altitude and correlation of ventricular size with acute mountain sickness: Brian Cummins' results from the 1985 Kishtwar expedition

Title

Direct measurement of intracranial pressure at high altitude and correlation of ventricular size with acute mountain sickness: Brian Cummins' results from the 1985 Kishtwar expedition

Creator

Wilson MH; Milledge J

Publisher

Neurosurgery

Date

2008

Subject

Humans; Male; Young Adult; Adult; Middle Aged; Severity of Illness Index; Intracranial Pressure; Acute Disease; adolescent; Tomography; X-Ray Computed; India; Altitude Sickness/diagnosis/etiology/physiopathology; Brain/complications/physiopathology; Cerebral Ventricles/physiopathology; Expeditions; Experimental; Headache/etiology; Hypoxia; Implants; Intracranial Hypertension/diagnosis/etiology; Physical Exertion; Telemetry/instrumentation

Description

OBJECTIVE AND IMPORTANCE: The "tight-fit" hypothesis and subsequent current understanding of acute mountain sickness (AMS) is that individuals with less compliant cerebrospinal fluid systems (smaller ventricles and cerebrospinal fluid spaces) have a greater increase in intracranial pressure (ICP) for a given increase in brain volume as a result of hypoxic cerebral edema. There has only been 1 study of direct (telemetric) ICP measurement at high altitude. This was performed in 1985 on 3 subjects by Brian Cummins up to a maximum height of 16,500 ft (5030 m). The group also investigated the "tight-fit" hypothesis by correlating computed tomographic scans that measured ventricular size (read blindly) with headache score and AMS symptomatology in 10 subjects. Unfortunately, the data were thought to have been destroyed by fire, and, hence, the findings were not published. The data have now been rediscovered, and this article reviews the methodology and findings of this unique piece of work. RESULTS: The ICP monitoring study demonstrated that ICP remained normal at rest at all altitudes; however, in the single subject with AMS, there was a dramatic increase in ICP even on minimal exertion. The computed tomographic scan analysis of brain compliance demonstrated an inverse correlation between ventricular size and headache score. CONCLUSION: This unique research, which is unlikely to ever be repeated, is the only report of direct ICP measurement at high altitude. This and the computed tomographic study provide the first objective evidence supporting the "tight-fit" hypothesis of AMS.
2008

Rights

Article information provided for research and reference use only. PedPalASCNET does not hold any rights over the resource listed here. All rights are retained by the journal listed under publisher and/or the creator(s).

Type

Journal Article

Citation List Month

Backlog

Citation

Wilson MH; Milledge J, “Direct measurement of intracranial pressure at high altitude and correlation of ventricular size with acute mountain sickness: Brian Cummins' results from the 1985 Kishtwar expedition,” Pediatric Palliative Care Library, accessed April 24, 2024, https://pedpalascnetlibrary.omeka.net/items/show/14026.